7-branch Stainless Steel Radiant Manifold Set

7-branch Stainless Steel Radiant Heat Manifold Set w/ 1/2" PEX adapters

Brand: Rifeng

Mfr Part#: SSM107

Availability: In Stock
Usually ships: Today, if ordered by 3pm
Qty Price
$198.95 / each & Free Shipping
  • Description
  • Reviews (2)
  • FAQs (3)

1/2" PEX adapters are included by default. For other size adapters (free upgrade) make a note at checkout.

 

7-branch Premium Stainless Steel Manifold Set for Radiant Heating Applications. Comes pre-assembled, and includes the following components:

 

(1) Supply side stainless steel PEX manifold with (7) adjustable flow meters (indicators) and (7) PEX tubing outlets.

 

(1) Return side stainless steel PEX manifold with (7) manual balancing valves and (7) PEX tubing outlets.

 

(2) 1" IPS Shut-off ball valves (1/4-turn) - one for each manifold (blue handle for return manifold and red handle for supply).

 

(2) Temperature gauges on both manifolds to monitor supply and return water temperatures.

 

(1) Float-type air vent to eliminate air from the system - on return side (air vent cap included for pressure testing purposes).

 

(2) Drain valves with 3/4" garden hose connection and a cap.

 

(14) Compression-style adapters for 1/2" PEX tubing.

 

(2) Wall mounting brackets.

 

Technical specifications:

Manifold's PEX outlets are 2" OC (on center).

Overall height (when installed): 14.5";

Overall width (with shut-of valves): 20.75";

Supply and return manifolds are at 8.25" OC spacing.

 

Compatible with any ASTM F876/F877 PEX tubing (Bow, Viega, Everhot, Zurn, Nibco. etc.)

7-branch Stainless Steel Radiant Heat Manifold Set w/ 1/2" PEX adapters has an average 4.5 out of 5 rating based on 2 user reviews.
 
Easy to Use-- Excellent workmanship
By Verified Buyer (from Trout Creek, Montana) on 7/21/2015
Well crafted and easy to use. Simple bolt on installation. Now I have to finish the rest of the house!
Was this review helpful?  Yes / No
 
awsome design
By DWENGMA (from WOOSTER, OHIO) on 10/3/2011
much better than copper manifold that is cheap and u have to solder fittings on. this made job very easy and fast. just love it
Was this review helpful?  Yes / No
Indicate an email address where you wish to receive the answer to your question.
Image CAPTCHA
Enter numbers shown above without spaces. This step helps us to prevent automatic submissions.
I assumed I could turn the white return side knobs and the knobs under red caps on the supply side to completely close each port. However, the supply side still drips even if turned all the way in to lowest flow. Return side seems to hold pressure. Must I cap supply outlets or add an external shutoff for a partial install/test?
Read 1 answer
The pressure test is done when PEX tubing is already connected to the manifold. Flow meters, therefore, while able to reduce the flow to a minimum, are not really intended to be use as shut-off valves. If the manifold is not yet connected to main supply and return lines, one of the shut-off ball valves is closed, and the test kit with gauge (such as #TESTKIT) is connected to the other valve. All of the flow meters and balancing valves remain fully open during the pressure testing. If the manifold is already connected to the system, then pressure gauge and Schrader valve can be installed elsewhere in the system, with both supply and return valves on the manifold in open position. Likewise, flow meters and balancing valves should be open. Note that the cap on the air vent which comes with the manifold should be removed or loosened once pressure testing is complete in order for it to function properly.
Answered on 10/12/2015 by PexUniverse Customer Service
Was this answer helpful?  Yes / No
Do these manifolds work with pex - al - pex or are different fittings required?
Read 1 answer
2 of 2 people found this answer helpful.
1/2" PEX adapters are included by default. You can change them to 1/2" PEX-AL-PEX adapters at no extra charge by leaving a note at the checkout.
Answered on 3/27/2015 by PexUniverse Customer Service
Was this answer helpful?  Yes / No
can the manifold be ordered with the inlet and outlet on the right side instead of the left?
Read 1 answer
3 of 3 people found this answer helpful.
The inlet/outlet valves are designed for installation on either side of the manifold to accommodate project specifics.
Answered on 9/24/2012 by PexUniverse Customer Service