Taco PC700-2 Boiler Reset Control

Taco PC700-2 Boiler Reset Control
Click on image to enlarge
Taco PC700-2 Boiler Reset Control
Taco

Brand:

SKU#:

UPC#:

Taco

PC700-2

687752239966

No reviews yet

Availability: In Stock
Usually ships: within 1 business day
Qty Price
$275.95 / each + Free Shipping
Add to cart McAfee SECURE sites help keep you safe from identity theft, credit card fraud, spyware, spam, viruses and online scams

Product Description:


Taco Boiler Reset Control model PC700-2 is designed to improve performance in your hot water heating systems by regulating the supply water temperature of a single boiler based on the outdoor temperature. The control utilizes a heating curve to set the relationship between outdoor temperature and supply water temperature to provide optimum control and comfort.

Thanks to its integral microprocessor, the Taco PC700-2 is able to continuously adjust the boiler differential to avoid boiler short-cycling and large temperature swings, Standard functions include warm weather shut down, minimum boiler supply temperature setting, and a starting water temperature setting. A liquid crystal display clearly shows the boiler supply temperature and other monitored temperatures and settings for simple and effective control.

 

Also included in the package: Input (Boiler) Sensor and Output (Outdoor) Sensor.

 

Features:

Control: Microprocessor PI Control. This is not a safety ( limit ) control.

Dimensions: 4 3/4” H x 2 7/8” W x 7/8” D

Approvals: CSA NRTL/C; Meets ICES & FCC regulations for EMI/RFI

Ambient Cond.: Indoor use only

Power Supply: 24 VAC 3VA (Powered by -EXP Control)

Relays: 24 V (ac) 5 A, pilot duty 240 VA

Sensors: 1 Outdoor Air and 1 Supply Water

Boiler Start: 35 to 150°F ( 2 to 66°C )

Outdoor Start: 35 to 85°F ( 2 to 29°C )

Boiler Design: 70 to 220°F ( 21 to 104°C )

Outdoor Design: -60 to 32°F ( -51 to 0°C )

Boiler Minimum: Off, 80 to 180°F ( 27 to 82°C )

Differential: Auto, 2 to 42°F ( 1 to 24°C )

WWSD: Off, 35 to 100°F ( 2 to 38°C )

Units: °F, °C

 

Documentation:

Instruction Sheet for Taco PC700-2 Boiler Reset Control (pdf)

Application Guide for Taco PC700 Outdoor Boiler Reset Control (pdf)

No reviews yet
Write a Review

The following was added to your shopping cart: X
X

Forgot Your Password?


Enter your e-mail address below.
You will receive an e-mail
with password reset instructions.